Product Details:
|
Rated Voltage: | 220V/110V | Application: | Separated Pressurized Solar System |
---|---|---|---|
Model: | SR208C | Color: | Grey |
Temperature Range: | 0~99℃ | Electromagnetic Valve: | DC 12V AC 220V |
Type: | Intelligent Solar Water Heater Controller | Water Proof Grade: | IP41 |
High Light: | Split Pressure SR208C Solar Controller,WIFI SR208C Controller,WIFI SR208C Solar Controller |
SR208C WIFI Controller Split Pressure Solar Water Heater SR208C Controller
SR208C WIFI.
A BRIEF DESCRIPTION
Temperature measurement accuracy:0.1
Conventional/HE pump both available on
APPLICATIONS CAPACITY
Max.number of collectors:1
Max.number of storage tanks:1
Max.number of relays:2
Max.number of sensors:3
Max.number of visualization application system:1
TECHNICAL DATA
Size of Controller:178mm x120mm x43mm
Power supply:AC100-240V,50-60Hz. .
Power consumption: < 2.5W
Accuracy of temperature measuring: ± 0.1oC
Range of collector temperature measuring: -10oC ~220oC
Range of tank temperature measuring: 0oC ~110oC
Suitable power of pump: 1 pump possible to be connected, output power < 300W .
Suitable power of HK (backup heating): 1pc ˂500W .
Inputs: 3 sensors,
1pcs*Pt1000 sensor (≤500oC) for collector (silicon cable≤280oC),
2pcs*NTC10K, B3950 sensor (≤ 135oC) for tank, (PVC cable ≤105oC),
Outputs:2 relays, for circulation pump and backup heating
Ambient temperature:-10oC ~ 50oC.
Water proof grade: IP41
Size of Controller:178mm x120mm x43mm
Power supply:AC100-240V50-60Hz. .
Power consumption: < 2.5W
Accuracy of temperature measuring: ± 0.1oC
Range of collector temperature measuring: -10oC ~220oC
Range of tank temperature measuring: 0oC ~110oC
Suitable power of pump: 1 pump possible to be connected output power < 300W .
Suitable power of HK (backup heating): 1pc ˂500W .
Inputs: 3 sensors
1pcs*Pt1000 sensor (≤500oC) for collector (silicon cable≤280oC)
2pcs*NTC10K B3950 sensor (≤ 135oC) for tank (PVC cable ≤105oC)
Outputs:2 relays for circulation pump and backup heating
Ambient temperature:-10oC ~ 50oC.
Water proof grade: IP41
AH Afterheating/thermostat
Password protection
LOAD Tank heating
OCEM Collector emergency shutdown
OCCO Collector cooling
OCMI Collector minimum temperature
OCFR Antifreeze
OTCO Tube collector
PUMP Pump control mode
OSYC System cooling
OSTC Tank cooling
MAN Manual mode
BLPR Blocking protection
OTDI Thermal Disinfection
UNIT C-F switch
BEEP beeper fault warning
Memory function
Screen protection
Trouble checking
Holiday function
The holiday function is used for operating the system when no water consumption is expected, e. g.
during a holiday absence. This function cools down the system in order to reduce the thermal
load.When bottom temperature of tank below down 35oC,the solar pump is deactivate.Manual of SR208C intelligent controller
Activate/deactivate this function:
►Press “ ” button for 3 seconds, “HDAY 05” displays on the screen
►Press “▲/▼”, to adjust holiday’s days, adjustable range 0-99 days
►Press “ ” for 3 seconds again, to adjust holiday’s days to 0,
►Press “ESC” to exit, holiday function is closed
Note:When you return from holiday, please deactivate this function in time.
WIFI Remote Control is available for SR208C WIFI only.
SR208C
SR208C Solar Controller Water Heater Controller for split solar system.
1 pt1000 and 2 ntc10k temperature
2 years warranty
Working Principle
1 collector array.
1 storage tank.
1 pump and auxiliary heating.
Description: The solar circuit pump (R1) is switched on as soon as the switch-on temperature difference (Delta Ton) between the collector array (T1) and the storage tank (T2) is reached.
If the temperature difference between the collector array (T1) and storage tank (T2) drops below the switch-off temperature difference (Delta T off), or the temperature of storage tank (T3) reaches the preset maximum storage temperature, then the solar circuit pump ( R1) is switched off.
Back-up heating by auxiliary boiler Within the preset time section of back-up heating, if the temperature T3 is below the switch-on temperature, then the circulation pump ( H1) of back-up heating is triggered, when T3 is heated to the switch-off temperature, circulation pump H1 of back-up heating is ceased.
1. Appearance of controller: 178mm×120mm×43mm
2. Power supply: AC230V±10%
3. Power consumption: < 3W
4. Accuracy of temperature measuring: ±2centigrade
5. Range of collector temperature measuring: -10~220centigrade
6. Range of tank temperature measuring: 0~110centigrade
7. Suitable power of pump: 3, <= 600W
8.inputs: 1 x Pt1000 sensor (<=500 centigrade) for collector (silicon cable<=280 centigrade),
9. 2 x NTC10K, B3950 sensor (<= 135centigrade) for tank, (PVC cable <=105centigrade),
10. Outputs: 1 relays, for circulation pumps
11. 1 relay for electrical heater
12. Ambient temperature: -10~50 centigrade
Main Functions
1.Main menu DT O & DT F Temperature difference function
2.Main menu-THET timing heating
3.TEMP Temperature main menu
4.EM Emergency collector temperature (emergency switch-off temperature of collector)
5.CMX Maximum limited collector temperature (collector cooling function)
6.CMN low temperature protection of collector
7.CFR frost protection of collector
8.SMX Maximum temperature of tank
9.REC Tank re-cooling function
10.Celsius and Fahrenheit temperature transferring
12.PASS Password setting
13.LOAD Recovery to factory setting
14.Manual heating
15.Temperature query function
16.Protection function
18.Anti-dry heating Protection
19.Screen protection
Technical datas:
Suitable for pressurized solar system
<1> Dmension: 178x120x43mm
<2> Power supply:200V-240V AC or 100V-130V AC,50-60Hz
<3> Power consumption: < 3W
<4> Accuracy of temperature measuring: ± 2oC
<5> Range of collector temperature measuring: -10oC ~200oC
<6> Range of tank temperature measuring: 0oC~110oC
<7> Suitable power of pump: 2 pumps possible to be connected, power of each pump < 200W .
<8> Inputs: 3 sensors,
1pcs*Pt1000 sensor (≤500oC) for collector (silicon cable≤280oC),
2pcs*NTC10K, B3950 sensor (≤ 135oC) for tank, (PVC cable ≤105oC),
<9> Outputs:2 relays, for circulation pumps or 3-way electromagnetic valve
<10> Ambient temperature:-10oC ~ 50oC.
<11> Water proof grade: IP40.
Main functions:
<1> Timing heating
<2> Temperature difference control 1*ΔT
<3> Collector emergency shutdown
<4> Collector cooling function
<5> Collector low temperature protection
<6> Collector frost protection
<7> Tank re-cooling function
<8> Celsius and Fahrenheit temperature switch
<9> Maximum temperature of tank ( 1*storage tank)
<10> Manual Control( for 2 outputs:P1,H1)
<11> Password setting
<12> Recovery to factory setting
<13> Manual Heating
<14> Temperature query function
<15> Memory Protection
<16> Screen protection
<17> Trouble shooting
<18> Trouble protection
<19> Trouble checking
Flat Panel Split Solar Water Heater
with Double Coils PTS-F2
Flat Panel Split Solar Water Heater with Double Coils PTS-F2 |
||||||||
Model | PTS-F2-15 | PTS-F2-20 | PTS-F2-25 | PTS-F2-30 | PTS-F2-40 | PTS-F2-50 | PTS-F2-100 | |
Flat Panel Solar Collector | Core material | Copper | ||||||
Coating | Copper aluminum cover coating of Blue Titanium Absorption rate: α=0.95 Reflection rate ε=0.04. | |||||||
Base plate | Marine-grade H3004 Aluminum, toughnessH32 Thickness 0.7mm | |||||||
Glass of panel | Special glass for panel With ANS1297-1-1975, BS6206A and JIS R3206 standards; toughness with AS2208-1978 and federal standards of United States. | |||||||
Panel Insulation | Bottom with fiberglass insulation ,Thickness 60mm,Density 20kg/m³; Side-thickness insulation:13mm; Density 23kg/m³; Thermal properties: R1.0 Thermal conductivity : 0.059W/m. | |||||||
Quantity (PCS) | 1 | 1 | 2 | 2 | 3 | 3 | 6 | |
Water Tank |
Capacity | 150L | 200L | 250L | 300L | 400L | 500L | 1000L |
Top Copper Coil (mm*M) | Φ16*15 | Φ16*15 | Φ16*15 | Φ16*15 | Φ16*15 | Φ16*20 | Φ19*30 | |
Bottom Copper Coil (mm*M) | Φ16*15 | Φ16*15 | Φ16*15 | Φ16*15 | Φ16*25 | Φ16*30 | Φ19*40 | |
Polyurethane Foaming (mm) | 55 | 50 | 50 | 50 | 60 | 60 | 100 | |
Outer Tank | Color Steel Plate/ Enamal White | |||||||
Φ470/0.5 | Φ550/0.5 | Φ580/0.5 | Φ580/0.5 | Φ700/0.5 | Φ700/0.5 | Φ1000/0.5 | ||
Inner Tank | SUS 304 2B , Working pressure-6 bar, Test pressure-12 bar | |||||||
Φ360/1.2 | Φ450/1.5 | Φ480/1.5 | Φ480/1.5 | Φ580*2.0 | Φ580*2.0 | Φ800/2.5 | ||
Electrical Heater | 1500W | 1500W | 2000W | 2000W | 2000W | 2000W | 4000W | |
Working Station | SR961S (Including controler & WILO PUMP) | |||||||
Expansion Tank | 8L | 8L | 8L | 8L | 12L | 12L | 24L |
Heat Pipe Split Solar Water Heater
with Double Coils PTS-H2
Heat Pipe Split Solar Water Heater with Double Coils PTS-H2 |
||||||||
Model | PTS-H2-15 | PTS-H2-20 | PTS-H2-25 | PTS-H2-30 | PTS-H2-40 | PTS-H2-50 | PTS-H2-100 | |
Heat Pipe Solar Collector | Tubes (PCS) | 15 | 20 | 25 | 30 | 40 | 50 | 100 |
Three Target Vacuum Tube | Diameter/Length: φ58mm/1800mm; High boron and silicon content 3.3; Structure:Gradual change SS-AL-Nx/Cu selective absorption coating; Vacuum Degree:P<=5*10-3; | |||||||
Heat Pipe | Condesor: φ14*70mm; Thickness: 0.5mm ; Material: red copper TU1+water; Transfer Power:>=150W; Working Pressure:4Mpa; Welding Pressure:4Mpa; | |||||||
Outer Shell/Bracket - Alluminum Alloy | Insulation Layer - Rock wool | Dustproof Rubber - EPDM | Dsily Heat Gain - 8.5MJ/m² | |||||
Inlet/outlet - 22mm/3/4" | Tailstock - ABS | Temperature - 250 °С | Work Pressure - 0.6MPa | |||||
Contour Area | 2.32m² | 3.10m² | 3.78m² | 4.52m² | 6.20m² | 7.56m² | 15.12m² | |
Aperture Area | 1.43m² | 1.89m² | 2.36m² | 2.83m² | 3.8m² | 4.72m² | 9.44m² | |
Absorption Area | 1.22m² | 1.62m² | 2.04m² | 2.43m² | 3.24m² | 4.06m² | 8.16m² | |
Quantity (PCS) | 15tubes*1 | 20tubes*1 | 25tubes*1 | 30tubes*1 | 20tubes*2 | 25tubes*2 | 25tubes*4 | |
Water Tank |
Capacity | 150L | 200L | 250L | 300L | 400L | 500L | 1000L |
Top Copper Coil (mm*M) | Φ16*15 | Φ16*15 | Φ16*15 | Φ16*15 | Φ16*15 | Φ16*20 | Φ19*30 | |
Bottom Copper Coil (mm*M) | Φ16*15 | Φ16*15 | Φ16*15 | Φ16*15 | Φ16*25 | Φ16*30 | Φ19*40 | |
Polyurethane Foaming (mm) | 55 | 50 | 50 | 50 | 60 | 60 | 100 | |
Outer Tank | Color Steel Plate/ Enamal White | |||||||
Φ470/0.5 | Φ550/0.5 | Φ580/0.5 | Φ580/0.5 | Φ700/0.5 | Φ700/0.5 | Φ1000/0.5 | ||
Inner Tank | SUS 304 2B , Working pressure-6 bar, Test pressure-12 bar | |||||||
Φ360/1.2 | Φ450/1.5 | Φ480/1.5 | Φ480/1.5 | Φ580*2.0 | Φ580*2.0 | Φ800/2.5 | ||
Electrical Heater | 1500W | 1500W | 2000W | 2000W | 2000W | 2000W | 4000W | |
Working Station | SR961S (Including controler & WILO PUMP) | |||||||
Expansion Tank | 8L | 8L | 8L | 8L | 12L | 12L |
24L |
Contact Person: Mr. Terry White
Tel: +86 135 1138 8384