Send Message
Home ProductsVacuum Tube Solar Collector

100 Tubes Evacuated Solar Collector Open Loop Circulation Room Hot Water Heating

Certification
China JIAXING PASSION NEW ENERGY TECHNOLOGY CO., LTD. certification
China JIAXING PASSION NEW ENERGY TECHNOLOGY CO., LTD. certification
Customer Reviews
Good Solar Water Heater, Good team saves my time , Thanks.

—— John Christopher from Spain

Thanks for visting us to solve my project issue.

—— Marco from Egypt

Good quality! High Efficiency! So glad to cooperate with you.

—— Pablo from Argentina

I'm Online Chat Now

100 Tubes Evacuated Solar Collector Open Loop Circulation Room Hot Water Heating

100 Tubes Evacuated Solar Collector Open Loop Circulation Room Hot Water Heating
100 Tubes Evacuated Solar Collector Open Loop Circulation Room Hot Water Heating 100 Tubes Evacuated Solar Collector Open Loop Circulation Room Hot Water Heating 100 Tubes Evacuated Solar Collector Open Loop Circulation Room Hot Water Heating

Large Image :  100 Tubes Evacuated Solar Collector Open Loop Circulation Room Hot Water Heating

Product Details:
Place of Origin: CHINA
Brand Name: PASSION/OEM
Certification: CE
Model Number: 100Tubes
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: Negotiable
Packaging Details: CARTONS/PLYWOOD CASE/PALLET
Delivery Time: 10 working days
Payment Terms: L/C, T/T, D/P
Supply Ability: 5000units/month

100 Tubes Evacuated Solar Collector Open Loop Circulation Room Hot Water Heating

Description
Model: 100 Tubes Use: Large Heating Project
Insulation: High Pressure Polyurethane Foam Evacuated Tube: Glass Tubular Vacuum Tube
Circulation Type: Open Loop Outer Tank: Stainless Steel
Inner Tank: Stainless Steel 304 Bracket: Stainless Steel 304
High Light:

vacuum tube hot water solar collector

,

solar evacuated tube collectors

 

100 Tubes Evacuated Solar Collector Open Loop Circulation Room Hot Water Heating

 

Product structure


1. vacuum tube.

2. shield ring.

3. polyurethane foam thermal insulation.

4 shell.

5 the retaining bolt.

6 inner tank.

7 pipe sealing ring.


Product features


1. The food-grade SUS304 stainless steel tank, corrosion resistance, the service life is long.
2. The non-pressure running and can be used for natural circulation system, the collector absorb surface is big, installation is simple.
3. All polyurethane foam heat preservation, high pressure foaming process, small coefficient of thermal conductivity, heat loss.
4. Designed for commercial building design, suitable for schools, dormitories, hotel, bath center and other public construction application.

 

MODEL PT-NC-50 PT-NC-60
TUBE QUANTITY(PCS) 50 60
TUBE SPACING(mm) 75 75
TUBE DIAMETER/LENGTH(mm) φ58/1800 φ58/1800
TUBE MATERIAL HIGH BOROSILICATE GLASS 3.3 HIGH BOROSILICATE GLASS 3.3
TUBE INNER/OUTER WALL THICKNESS(mm) 1.6/1.8 1.6/1.8
MANIFOLD MATERIAL/WALL THICKNESS(mm) SUS304/0.50 SUS304/0.50
JOINT PORT SPECIFICATION 1″ 1″
THERMAL INSULATION MATERIAL/THICKNESS(mm) POLYURETHANE FOAM/40 POLYURETHANE FOAM/40
COLLECTOR RATED PRESSURE(MPa) 0.003 0.003
COLLECTOR RUNNING TEMPERATURE Celsius <100 <100
COLLECTOR VOLUME(L) 145 175
COLLECTOR ABSORB AREA(m2) 4.8 5.8
COLLECTOR TOTAL AREA(m2) 7.72 8.24
RECOMMENDED FLOW(L/min) 5.76 6.96
INTERCEPT EFFICIENCY η0 0.62 0.62
HEAT LOSS COEFFICIENT a 3.0 3.0
COLLECTOR NET WEIGHT(kg) 12.5 129.5
HORIZONTAL INSTALLATION SIZE    
ANGLE 15° 15°
a (mm) 2060 2435
b (mm) 1974 2349
c (mm) 1860 2335
d (mm) 2023 2360
e (mm) 2200 2550
f (mm) 770 860
G (mm) 3715 3715
H (mm) 3560 3560
H/2 (mm) 1780 1780

 

Packaging & Delivery

Packaging Details:

Export carton for full container.

Delivery Detail:

7 days after receiving the deposit.

 

Payment term:

 

1. T/T 30% Deposit in advance and balance should be paid after receiving the B/L copy.

2. L/C at sight (if your quantity reaches 5*40’ HQ container)

3. Sample order or LCL: we accept western union and one touch business.

 

Warranty:

 

6 years international responsibility for U pipe solar collector and 15 years for vacuum tubes due to original quality problems.

 

Maintenance:

 

Maintenance of the system is very easy and includes the following tasks:

1. Cleaning

Regular rain should keep the evacuated tubes clean, but if particularly dirty they may be washed with a soft cloth and warm, soapy water or glass cleaning solution. If the tubes are not easily and safely accessible, high pressure water spray is also effective.

2. Leaves

During autumn, leaves may accumulate between or beneath the tubes. Please remove these leaves regularly to ensure optimal performance.

3. Broken tube

If a tube is broken it should be replaced as soon as possible to keep the system working. Any broken glass should be cleared away to prevent injury.

100 Tubes Evacuated Solar Collector Open Loop Circulation Room Hot Water Heating 0

 

Contact Details
JIAXING PASSION NEW ENERGY TECHNOLOGY CO., LTD.

Contact Person: Mr. Terry White

Tel: +86 135 1138 8384

Send your inquiry directly to us (0 / 3000)