Send Message
Home ProductsSolar Pump Station

Solar Pump Station SR982P for Split Solar Water Heater System including Controller and Pump

Certification
China JIAXING PASSION NEW ENERGY TECHNOLOGY CO., LTD. certification
China JIAXING PASSION NEW ENERGY TECHNOLOGY CO., LTD. certification
Customer Reviews
Good Solar Water Heater, Good team saves my time , Thanks.

—— John Christopher from Spain

Thanks for visting us to solve my project issue.

—— Marco from Egypt

Good quality! High Efficiency! So glad to cooperate with you.

—— Pablo from Argentina

I'm Online Chat Now

Solar Pump Station SR982P for Split Solar Water Heater System including Controller and Pump

Solar Pump Station SR982P for Split Solar Water Heater System including Controller and Pump
Solar Pump Station SR982P for Split Solar Water Heater System including Controller and Pump Solar Pump Station SR982P for Split Solar Water Heater System including Controller and Pump

Large Image :  Solar Pump Station SR982P for Split Solar Water Heater System including Controller and Pump

Product Details:
Place of Origin: CHINA
Brand Name: PASSION/OEM
Certification: CE
Model Number: SR982P
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: Negotiable
Packaging Details: CARTONS/PLYWOOD CASE/PALLET
Delivery Time: 3 working days
Payment Terms: L/C, T/T
Supply Ability: 10000units/month

Solar Pump Station SR982P for Split Solar Water Heater System including Controller and Pump

Description
Rated Voltage: 220V/110V Application: Solar Pump Station
Model: SR982P Pump: WILO
Using: Split Solar Water Heater System Colour: Silver
Pipe: Copper Accessories: Controller And Pump
High Light:

solar thermal pump station

,

solar working station

Solar Pump Station SR982P for Split Solar Water Heater System including Controller and Pump
 
Technical data:


Dimension: 420mm*280mm*155mm
Power supply:200V-240V AC or 100V-130V AC50-60Hz. .
Power consumption: < 3W
Accuracy of temperature measuring: ± 2oC
Range of collector temperature measuring: -10oC ~200oC
Range of tank temperature measuring: 0oC ~100oC
Suitable power of pump: 3 pumps possible to be connected power of each pump < 200W .

 


Suitable power electrical heating:1 relay for 1500W(1500w-4000w must be use SR802)
Inputs: 5sensors
7pcs*Pt1000 sensor (≤500oC) for collector (silicon cable≤280oC)
4pcs*NTC10K B3950 sensor (≤ 135oC) for tank (PVC cable ≤105oC)
Outputs:4 relays for circulation pumps or 3-way electromagnetic valve
Ambient temperature:-10oC ~ 50oC.
Water proof grade: IP42.
 
FUNCTIONS:
 
Pump support:
1. Can be support Normal Pump.
2. Can be support High Efficiency pump.


Functions operation and parameter setup (engineer grade)
1. DT Temperature difference for solar circuit pump
2. EMOF Maximum switch-off temperature of collector (for collector emergency close function)
3. CMX Maximum limited temperature of collector (collector cooling function)
4. CMN Low temperature protection of collector
5. CFR frost protection temperature of collector
6. REC Recooling temperature of tank
7. SMX1 Maximum temperature of tank 1
8. SMX2 Maximum temperature of tank 1
9. MAX1 Maximum switch-off temperature for heat transfer between tank and heat return
10. MIN1 Minmium switch-on temperature for heat transfer between tank and heat return
11. MAX2 Maximum switch-off temperature for heat transfer between heat exchanger and tank
12. MIN2 Minmium switch-on temperature for heat transfer between heat exchanger and tank
13. C_F Switch between Celsius and Fahrenheit

FUN Auxiliary functions
1. DVWG Anti legionnaires' function
2 SFB Switch-on/off of the solid fuel boiler
3. SFON Minimum switch-on temperature of tank
4. SFOF Maximum switch-off temperature of tank
5. MAX3 Maximum switch-off temperature of solid fuel boiler
6. MIN3 Minimum switch-on temperature of solid fuel boiler
7. PUMP1 P1 pump operation mode selection
8. PUMP2 P2 pump operation mode selection
9. OHQM Thermal energy measuring
10. FTYPE Flow meter type selection
11. FMAX Flow rate
12. MEDT Type of heat transfer liquid
13. MED% Concentration of heat transfer liquid
14 Tank priority
15. pump Intermission function
16.COOL Tank cooling function
17.AHO Automatical thermostat function
18.BYPR Bypass function (high temperature)
19.HND Manual control
20.PASS Password set
21.REST Recovery to factory set
22."ON/OFF"Controller switch on/off button
23.Holiday function
24.Manual heating
25.Temperature checking function
26.Protection function
27.Memory protection
28.Screen protection
29.Pump P1/P2 dry running protection
30.Trouble shooting
31.Trouble protection
32.Trouble checking

 

Set up clock/week

Functions operation and parameters setup (user grade)

1 THET Timing heating 37
2 CIRC DHW circuilation function activated /deactivated
3 tCYC Tempeature or time setting for DHW pump in three time sections